ROCK STAR is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, rein- forced with Non-Woven Polyester Carrier.

Rock Star

Description:

Rock Star is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, rein- forced with Non-Woven Polyester Carrier.

Rock Star proprietary waterproofing compound is formulated with high grade bitumen modified with Atactic polypropylene (APP) to increase elasticity, flexibility, and enhanced with admixture of Thermoplastic materials to gain high heat resistance, good elongation and low temperature flexibility. To improve the UV resistance and durability for The Product, the membrane is coated with Mineral Stabilizers.

Key Features:

  • High U.V. resistance (Mineral Finish).
  • Excellent thermal resistance.
  • Strong adhesion to substrate
  • Proven water impermeability.
  • Chemical resistance to wide range of light acidic, alkaline solutions and bacteria.

Reinforcement

There are several types of reinforcement materials used in bituminous membranes, including:

  • Non- woven Glass fiber Reinforcement: provides tensile strength and dimensional stability
  • Non-woven polyester fabric: provides tensile strength and stability
  • Non-woven Polyester reinforcement reinforced with fiberglass filaments composite : Very high tensile strength, excellent elongation properties and good dimensional stability.
  • Compound Base: High tensile strength and good dimensional stability 

The choice of reinforcement material depends on the specific requirements of the roofing system and the desired properties such as reflectivity, dimensional stability, and resistance to environmental factors.

Surface Finish

The surface finish of a bituminous membrane refers to the final appearance of the membrane once it has been installed on the roof. The surface finish can have an impact on the overall aesthetic of the roof, as well as its performance. Some common types of surface finishes for bituminous membranes include:

  • Sand finish: a rough, textured surface that helps to increase the coefficient of friction and improve slip resistance, Specially (White/Yellow)

  • Granulated finish: a surface that is covered with small, granulated particles, typically made of a durable material such as aluminum oxide. This finish provides a high level of slip resistance and UV stability. Available in colors (Red, Grey, Green)

  • Smooth finish: a smooth surface that provides a sleek, modern appearance, but may have lower slip resistance compared to other finishes.

The choice of surface finish depends on the specific requirements of the roofing system, such as the desired level of slip resistance and the type of roof deck.

Methods of Installation

The installation methods for APP (Atactic Polypropylene) bituminous membrane vary depending on the specific requirements of the roofing system and the type of membrane being used. Some common methods of installation include:

  • Heat welded seam method: involves heating the overlapped edges of the membrane with a propane torch to create a seamless, watertight bond between the two pieces of membrane.

  • Self-adhesive method: involves removing the release paper from the self-adhesive backing on the membrane and pressing it onto the roof deck.

  • Torch-on method: involves heating the bituminous membrane with a torch and then pressing it onto the roof deck, where it will fuse and adhere to the surface.

  • Mechanically fastened method: involves using special mechanical fasteners to attach the membrane to the roof deck.

The choice of installation method will depend on factors such as the type of roof deck, the local building codes and regulations, and the desired level of seam strength and durability. It is recommended to seek the guidance of a professional roofing contractor for the installation of an APP bituminous membrane.

Rock Star Membrane Characteristics

Test Test Method Tolerance Result Unit الاختبار
Thickness EN 1849-1 ±5% 4 mm السمك
Width EN 1848-1 ±1% 1 m العرض
Length EN 1848-1 ±1% 10 m الطول
Straightness EN 1848-1 - ± 6 mm درجة اإلستقامة
Softening Point (R&B) ASTM D-36 150 0C درجة التطرية
Flexibility at low temperature EN 1109 ASTM D-5147 - 0 : ±2 0C المرونة عند درجات الحرارة المنخفضة
Flow resistance at elevated temperature  EN 1110 ASTM D-5147 -10 120 0C الثبات عند درجات الحرارة العالية
Tensile Strength-Longitudinal EN 12311-1ASTM D-5147 ± 20% 650 N/5cm مقاومة الشد القصوي-طوليا
Tensile Strength-Transverse EN 12311-1ASTM D-5147 ± 20% 400 N/5cm مقاومة الشد القصوي-عرضيا
Elongation @Break -Longitudinal EN 12311-1ASTM D-5147 ± 15 40 % معدل اإلستطالة - طوليا
Elongation @Break -Transverse EN 12311-1ASTM D-5147 ± 15 45 % معدل اإلستطالة - عرضيا
Tearing Strength-Longitudinal EN 12310-1 200 N مقاومة التمزق-طوليا
Tearing Strength-Transverse EN 12310-1 215 N مقاومة التمزق-عرضيا
Tensile Tear Resistance-Longitudinal ASTM D-5147 D-4073 ± 20% 400 N مقاومة  التمزق بطريقة الشد-طوليا
Tensile Tear Resistance-Transverse ASTM D-5147 D-4073 ± 20% 350 N مقاومة التمزق بطريقة الشد-عرضيا
Resistance to Static Loading EN 12730 10 Kg مقاومة الإختراق الإستاتيكى
Resistance to Impact Loading EN 12691 800 mm مقاومة االإختراق الديناميكى
Shear Resistance of joint L/T EN 12317-1 ± 20% 650/400 N/5cm مقاومة الشد عند منطقة التركيب (طوليا/عرضيا)
Dimensional Stability L/T EN 1107-1 - 1 % ثبات األبعاد
Adhesion to concrete Pelage UEATC - 20 N/5cm قوة اإللتصاق باالسطح الخرسانية
Water absorption ASTM D-5147 0.15 %  درجة إمتصاص الماء
Fire Classification - Extemal Fire Performance EN 13501-5 - F roof - تصنيف الحريق-أداء الحريق الخارجي
Reaction to fire EN 13501-1 - E - رد الفعل عند التعرض للنار
Water Impermeability at Low Pressure EN 1928 method A - Pass 60Kpa عدم نفاذية الماء للضغط المنخفض
Water Impermeability at High Pressure EN 1928 method B - Pass 200Kpa عدم نفاذية الماء للضغط المرتفع
Thermal Ageing in air (in oven 4 weeks at 70 ± 2°C) EN 1296 - Pass - الإهتراء نتيجة التسخين
Ageing Due to Atmospheric Agents (U.V. Test weathering) ASTM G 53 UNI 8202/29 - Pass - مقاومة التقادم لالشعة فوق البنفسجية
Average loss of slates EN 12039 30 % متوسط الفاقد من الحبيبات

Note 

•  Products could vary in: Thickness - 3:4mm

•  ± All Tolerances according to UEAtc Directives

•  PES: Non-Woven Polyester Reinforcement Carrier

Related Products

Rockwool Blankets (Rolls)

Rockwool Blankets (Rolls)

Rockwool blanket insulation is a type of flexible insulation made from spun mineral wool, which is derived from a mixture of volcanic rock and slag. Rockwool Rolls are high performance solution for thermal & acoustic insulation for a range of commercial and industrial Buildings.

Rockwool Boards (Slabs)

Rockwool Boards (Slabs)

ROCKAL Rockwool Boards are composed of mineral rock fibers, processed from volcanic basaltic rocks, Fibers are bonded together with a thermosetting binder which gives the flexibility & resilience to the product.

Rockwool Pipe Sections

Rockwool Pipe Sections

Rockwool pipe section is a type of insulation material made from rock minerals (such as basalt and slag) that have been melted at high temperatures and then spun into fibers. Rockwool pipe section is commonly used to insulate pipes and ductwork in building and HVAC systems.

Rock Star

Rock Star

ROCK STAR is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, rein- forced with Non-Woven Polyester Carrier.

Rock  Torch

Rock Torch

ROCK TORCH is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, reinforced with Non-Woven Reinforcement composite with fiberglass.

Rock Plast

Rock Plast

ROCK PLAST is a Plastomeric high performance, prefabricated, modified bitumen waterproofing membrane consisting of proprietary waterproofing bitumen compound, reinforced with Non-Woven Polyester Carrier.